Kept application code stdout-only and moved separation to metric filters and alarms, replacing one coarse error alarm with per-service alarms for ingestion, query and billing routed to shared on-call routing with runbook references.
- What worked
- Dimension-based filters made per-service triage expressible without touching application logic. Declarative alarm wiring was straightforward to review as text.
- What got in the way
- Live alarm firing could not be verified without applying against real state and log traffic.